TY - JOUR
T1 - Comparison of a standard and a high-concentration contrast medium protocol for MDCT angiography of the lower limb arteries
AU - Meyer, B. C.
AU - Klein, S.
AU - Krix, M.
AU - Aschoff, A. J.
AU - Wacker, F. K.
AU - Albrecht, T.
PY - 2012
Y1 - 2012
N2 - Purpose: To prospectively compare a compact bolus (CB) injection protocol using high-iodine concentration contrast medium with a standard bolus (SB) injection protocol at equi-iodine doses for run-off computed tomographic angiography (CTA). Materials and Methods: 64 patients with suspected peripheral arterial disease who underwent 40 or 64-slice run-off CTA were included in this IRB-approved study. Patients were randomized to undergo the CB protocol (32 patients, iomeprol 400mgI/mL, 100 mL, 4 mL/sec) or the SB protocol (32 patients, iomeprol 300mgI/mL, 134 mL, 4 mL/sec). Luminal contrast density (CD) values were measured and arterial opacification (AO) was scored (5-point scale). Cases of venous overlay or bolus overriding were documented. Results: Overall arterial CD was significantly higher with the compact bolus (CB: 279 ± 57HU, SB: 234 ± 32HU, p = 0.0017). Segmental CD was significantly higher (p< 0.05) in 7 of 16 evaluated segments. Patency-based comparison revealed superior AO in vessels with relevant (50 - 99 %) stenoses (CB: 4.54 vs. SB: 4.18, p = 0.04). Contrast bolus overriding without pathological reasons, i. e., acute occlusions, was noted in one patient in each group. Venous overlay was observed less frequently in the CB group (CB vs. SB: 12 vs. 19 patients, n. s.; 29 of 64 legs [45 %] vs. 44 of 64 legs [69 %], p = 0.01). Conclusion: At equi-iodine doses, the CB protocol led to a quantitatively and qualitatively higher arterial opacification compared to the SB protocol. Therefore, a CB protocol should be favored for run-off CTA.
AB - Purpose: To prospectively compare a compact bolus (CB) injection protocol using high-iodine concentration contrast medium with a standard bolus (SB) injection protocol at equi-iodine doses for run-off computed tomographic angiography (CTA). Materials and Methods: 64 patients with suspected peripheral arterial disease who underwent 40 or 64-slice run-off CTA were included in this IRB-approved study. Patients were randomized to undergo the CB protocol (32 patients, iomeprol 400mgI/mL, 100 mL, 4 mL/sec) or the SB protocol (32 patients, iomeprol 300mgI/mL, 134 mL, 4 mL/sec). Luminal contrast density (CD) values were measured and arterial opacification (AO) was scored (5-point scale). Cases of venous overlay or bolus overriding were documented. Results: Overall arterial CD was significantly higher with the compact bolus (CB: 279 ± 57HU, SB: 234 ± 32HU, p = 0.0017). Segmental CD was significantly higher (p< 0.05) in 7 of 16 evaluated segments. Patency-based comparison revealed superior AO in vessels with relevant (50 - 99 %) stenoses (CB: 4.54 vs. SB: 4.18, p = 0.04). Contrast bolus overriding without pathological reasons, i. e., acute occlusions, was noted in one patient in each group. Venous overlay was observed less frequently in the CB group (CB vs. SB: 12 vs. 19 patients, n. s.; 29 of 64 legs [45 %] vs. 44 of 64 legs [69 %], p = 0.01). Conclusion: At equi-iodine doses, the CB protocol led to a quantitatively and qualitatively higher arterial opacification compared to the SB protocol. Therefore, a CB protocol should be favored for run-off CTA.
KW - CT angiography
KW - extremities
KW - vascular
UR - https://www.scopus.com/pages/publications/84861458990
UR - https://www.scopus.com/inward/citedby.url?scp=84861458990&partnerID=8YFLogxK
U2 - 10.1055/s-0031-1299412
DO - 10.1055/s-0031-1299412
M3 - Article
C2 - 22473508
AN - SCOPUS:84861458990
SN - 1438-9029
VL - 184
SP - 527
EP - 534
JO - RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren
JF - RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren
IS - 6
ER -