TY - JOUR
T1 - Assessing regional hepatic function changes after hypertrophy induction by radioembolisation
T2 - comparison of gadoxetic acid-enhanced MRI and 99mTc-mebrofenin hepatobiliary scintigraphy
AU - Fabritius, Matthias P.
AU - Garlipp, Benjamin
AU - Öcal, Osman
AU - Puhr-Westerheide, Daniel
AU - Amthauer, Holger
AU - Geyer, Thomas
AU - Holzgreve, Adrien
AU - Ricke, Jens
AU - Kupitz, Dennis
AU - Grosser, Oliver S.
AU - Omari, Jazan
AU - Pech, Maciej
AU - Seidensticker, Max
AU - Grawe, Freba
AU - Seidensticker, Ricarda
N1 - Publisher Copyright:
© 2024, The Author(s).
PY - 2024/12
Y1 - 2024/12
N2 - Background: To compare Gd-ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and 99mTc-labelled mebrofenin hepatobiliary scintigraphy (HBS) as imaging-based liver function tests after unilateral radioembolisation (RE) in patients with primary or secondary liver malignancies. Methods: Twenty-three patients with primary or secondary liver malignancies who underwent Gd-EOB-DTPA-enhanced MRI within a prospective study (REVoluTion) were evaluated. REVoluTion was a prospective open-label, non-randomised, therapy-optimising study of patients undergoing right-sided or sequential RE for contralateral liver hypertrophy at a single centre in Germany. MRI and hepatobiliary scintigraphy were performed before RE (baseline) and 6 weeks after (follow-up). This exploratory subanalysis compared liver enhancement on hepatobiliary phase MRI normalised to the spleen (liver-to-spleen ratio (LSR)) and the muscle (liver-to-muscle ratio (LMR)) with mebrofenin uptake on HBS for the total liver (TL) and separately for the right (RLL) and left liver lobe (LLL). Results: Mebrofenin uptake at baseline and follow-up each correlated significantly with LSR and LMR on MRI for TL (≤ 0.013) and RLL (≤ 0.049). Regarding the LLL, mebrofenin uptake correlated significantly with LMR (baseline, p = 0.013; follow-up, p = 0.004), whereas with LSR, a borderline significant correlation was only seen at follow-up (p = 0.051; p = 0.046). Conclusion: LSRs and LMR correlate with mebrofenin uptake in HBS. This study indicates that Gd-EOB-DTPA-enhanced MRI and 99mTc-labelled mebrofenin HBS may equally be used to assess an increase in contralateral liver lobe function after right-sided RE. Relevance statement: MRI may be a convenient and reliable method for assessing the future liver remnant facilitating treatment planning and monitoring of patients after RE-induced hypertrophy induction. Key points: • Both MRI and HBS can assess liver function after RE. • Liver enhancement on MRI correlates with mebrofenin uptake on HBS. • MRI might be a convenient alternative for estimating future liver remnants after hypertrophy induction. Graphical Abstract: [Figure not available: see fulltext.]
AB - Background: To compare Gd-ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and 99mTc-labelled mebrofenin hepatobiliary scintigraphy (HBS) as imaging-based liver function tests after unilateral radioembolisation (RE) in patients with primary or secondary liver malignancies. Methods: Twenty-three patients with primary or secondary liver malignancies who underwent Gd-EOB-DTPA-enhanced MRI within a prospective study (REVoluTion) were evaluated. REVoluTion was a prospective open-label, non-randomised, therapy-optimising study of patients undergoing right-sided or sequential RE for contralateral liver hypertrophy at a single centre in Germany. MRI and hepatobiliary scintigraphy were performed before RE (baseline) and 6 weeks after (follow-up). This exploratory subanalysis compared liver enhancement on hepatobiliary phase MRI normalised to the spleen (liver-to-spleen ratio (LSR)) and the muscle (liver-to-muscle ratio (LMR)) with mebrofenin uptake on HBS for the total liver (TL) and separately for the right (RLL) and left liver lobe (LLL). Results: Mebrofenin uptake at baseline and follow-up each correlated significantly with LSR and LMR on MRI for TL (≤ 0.013) and RLL (≤ 0.049). Regarding the LLL, mebrofenin uptake correlated significantly with LMR (baseline, p = 0.013; follow-up, p = 0.004), whereas with LSR, a borderline significant correlation was only seen at follow-up (p = 0.051; p = 0.046). Conclusion: LSRs and LMR correlate with mebrofenin uptake in HBS. This study indicates that Gd-EOB-DTPA-enhanced MRI and 99mTc-labelled mebrofenin HBS may equally be used to assess an increase in contralateral liver lobe function after right-sided RE. Relevance statement: MRI may be a convenient and reliable method for assessing the future liver remnant facilitating treatment planning and monitoring of patients after RE-induced hypertrophy induction. Key points: • Both MRI and HBS can assess liver function after RE. • Liver enhancement on MRI correlates with mebrofenin uptake on HBS. • MRI might be a convenient alternative for estimating future liver remnants after hypertrophy induction. Graphical Abstract: [Figure not available: see fulltext.]
KW - Gadolinium ethoxybenzyl DTPA
KW - Liver
KW - Magnetic resonance imaging
KW - Radioembolisation
KW - Technetium Tc 99 m mebrofenin
UR - http://www.scopus.com/inward/record.url?scp=85183423598&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85183423598&partnerID=8YFLogxK
U2 - 10.1186/s41747-023-00409-x
DO - 10.1186/s41747-023-00409-x
M3 - Article
C2 - 38282160
AN - SCOPUS:85183423598
SN - 2509-9280
VL - 8
JO - European radiology experimental
JF - European radiology experimental
IS - 1
M1 - 15